The yellow triangle indicates various trouble that your alarm system may experience, check carefully the display to find out what the issue is exactly. This alarm system accepts military time format only ( for example 7PM = 19:00 hours).Īs you can see, you can fix the majority of the issues by yourself and usually, it may take a while for the beeping to go away (there’s no need to do anything, the system will automatically get silenced). To change the time on the clock on the ADT DSC Impassa Alarm system you need to press star*-6-your mastercode-1.
#Dsc alarm panel trouble light update
Simply update to the correct time and date. Time and Date – Your system clock is incorrect. Press 6 on the keypad and the system will display the zone that is having issues. Zone Tamper – One of your zones has been tampered with. Then go to that area and inspect the contacts or whatever device is running there. Press 5 on the keypad to see which zone is currently experiencing trouble. Zone is open – One of the zones has an issue. You can call ADT support to perform a test or investigate the issue further. Check your phone line and ensure that it’s working properly.Ĭommunication Fault – The panel and ADT central station aren’t communicating properly. Phone Connection – It indicated that there could be a problem with the telephone line. After replacing the battery, disarm and arm the system. Buy a replacement battery online (take out the old and purchase the same model, usually, the battery is CR123A). All you have to do is replace the battery. Low Battery – It means that one of your zones is running on a low battery, the panel will tell you which zone exactly is having an issue. To test it out, you may try to charge your phone from the same outlet (to see if there’s power). Check the power outlet where the system is plugged in, inspect the cable, make sure nothing is loose. You’ll know this because the keypad will not make any beeping sound, but it will light up (using the backup battery). Below we’ve listed the most common issues that you should check when you see the yellow triangle on the ADT alarm panel.ĪC Power Loss – The system is not getting powered. If the beeping is bothering you, you can press the # symbol on the keypad and the warning sound will get silenced. Once you press that code, your zone light should light up and the panel will display any trouble issues. To find out what kind of problem your alarm system is experiencing, simply press *2 (star then 2) on your keypad. There are seven different issues that are noted by the yellow triangle symbol (the so-called trouble condition). If you see this symbol on your alarm panel, it means that there’s an issue with the system that needs to be addressed as soon as possible. The yellow triangle on the ADT Alarm system is known as the trouble light. Sometimes this yellow triangle is followed by the system beeping twice every 10 seconds. If your system has been fine for several years and then all of a sudden you get a trouble light, the majority of the time it is a low battery.You may have noticed a yellow triangle symbol on your ADT DSC Impassa Alarm system and probably you want to know what it means. From this point on, you can take the information you found and take it to the next step. If no lights show possible Fire Trouble To Reset Smoke Detectors hit * 72 (If this does NOT reset smoke detector set for service, smoke is bad) This is exactly how techs check to see what is wrong with your system.
#Dsc alarm panel trouble light code
Press 7 again to find which zone Zone Light 8 - Loss of System Clock (* 6 + Master Code + 1 + Time and Date (1pm 12/26 2000 would be 1300122600) Pre ss 6 again to show zone Zone Light 7 - Zone Low Battery Press 5 again to show zone Zone Light 6 - Zone Tamper Light 8 = 5204 Power Supply Module AC Fail.Light 7 = 5204 Power Supply Module Low Battery.On your DSC Keypad, hit " * 2 " Zone light will turn on showing trouble Here is an easy way to tell what the trouble may be. If either of those are lit up, then your system is letting you know that something isn't right. Many people call and state that they have a trouble light or a triangle lit up on their keypad. Total Connect 2.0 Package Monitoring Add-Ons.Central Station Alarm Monitoring Services.